燃?xì)獍l(fā)電機(jī)啟停作業(yè)有很多要注意的地方,下面沼氣脫硫設(shè)備廠家就給大家總結(jié)了一下,希望大家都可以認(rèn)真閱讀,對(duì)大家有所幫助!
Gas generator start-up and shut-down operation has a lot to pay attention to, below the methane desulfurization equipment manufacturers to summarize for you, I hope you can read carefully, to help you!
一、準(zhǔn)備工作
I. Preparations
1、檢查燃?xì)獍l(fā)電機(jī)的預(yù)熱系統(tǒng)、水循環(huán)系統(tǒng)是否正常;
1. Check whether the preheating system and water circulation system of gas generator are normal.
2、檢查氣路上各閥門的狀態(tài),檢查發(fā)電機(jī)通負(fù)載電路開(kāi)關(guān)狀態(tài);
2. Check the status of the valves on the gas path and the on-off status of the load circuit of the generator.
3、檢查發(fā)電機(jī)組是否固定牢固,各個(gè)電線接頭有無(wú)脫落。
3. Check whether the generator set is fixed firmly and whether the connection of each wire has fallen off.
4、檢查機(jī)組機(jī)油,冷卻水、電池液是否足夠,有無(wú)滲漏;
4. Check whether the oil, cooling water and battery liquid are enough and whether there is leakage.
5、檢查顯示屏上電池電壓,有無(wú)故障報(bào)警,若當(dāng)前有故障報(bào)警,消除故障后,取消報(bào)警,否則發(fā)電機(jī)無(wú)法啟動(dòng);
5. Check the battery voltage on the display screen and alarm if there is a fault. If there is a fault alarm at present, after eliminating the fault, cancel the alarm, otherwise the generator can not start.
二、操作要求
II. Operational requirements
1、熟悉發(fā)電機(jī)操作步驟,嚴(yán)格執(zhí)行本作業(yè)指導(dǎo)卡;
1. Familiar with generator operation procedures, strictly implement the operation guidance card;
2、啟動(dòng)后必須定時(shí)觀測(cè)機(jī)組工作狀況。
2. The working condition of the unit must be observed regularly after start-up.
三、操作步驟
III. Operational steps
㈠ 啟動(dòng)燃?xì)獍l(fā)電機(jī)
A Start-up Gas Generator
1、打開(kāi)氣路上所有閥門,調(diào)整進(jìn)發(fā)電機(jī)天然氣壓力至15mbar(1.5KPa)左右;
1. Open all valves on the gas path and adjust the natural gas pressure into the generator to about 15 bar (1.5 KPa);
2、旋轉(zhuǎn)控制面板上按鈕至“啟動(dòng)”位置,啟動(dòng)發(fā)電機(jī);
2. Rotate the button on the control panel to the "start" position and start the generator.
3、機(jī)組啟動(dòng)后檢查各參數(shù)顯示是否正常(電壓、頻率、水溫、油壓等),機(jī)組各部分有無(wú)滲漏;
3. Check whether the parameters of the unit are normal (voltage, frequency, water temperature, oil pressure, etc.) and whether there is leakage in each part of the unit after start-up.
4、閉合機(jī)組輸電開(kāi)關(guān),給負(fù)載供電;
4. Close the transmission switch of the unit to supply power to the load.
5、每30分鐘,記錄運(yùn)行參數(shù)(水溫、油壓、電壓、電流等)。
5. Record operation parameters (water temperature, oil pressure, voltage, current, etc.) every 30 minutes.
㈡ 停燃?xì)獍l(fā)電機(jī)
Gas Generator with Two Stops
1、斷開(kāi)發(fā)電機(jī)的負(fù)載開(kāi)關(guān),使機(jī)組空載運(yùn)行5分鐘;
1. Disconnect the load switch of the generator to make the unit run for 5 minutes without load.
2、旋轉(zhuǎn)控制面板上按鈕至“停機(jī)”位置。
2. Rotate the button on the control panel to the stop position.